Access Control : Installing and using ScanMan module : ScanMan configuration barcodes
 
ScanMan configuration barcodes
 
The information in this section applies to ScanMan module. The configuration barcodes shown are examples. You must modify according to the parameters for your site.
 
Note: To create these barcodes in Microsoft Word, use BC C39 2 to 1 Medium 18 points for barcodes and make sure to include an asterisk * before and after the barcode text. This font is installed as part of the Common Files application.
 
The following table summarizes all settings currently supported as of version 4.2.
 
 
Setting
Description
SETLOC
Sets the location
SETAUTOLOC
Automatically set a location at startup
SETOP
Sets the operator
SETAUTOOP
Automatically set an operator at startup
SETIP
IP address to connect to SalesEZ application
SETPORT
Port to connect to SalesEZ application
SETTO
Timeout in tenths of a second for SalesEZ application to timeout; usually three seconds or SETTO30
SETTD
Trickle delay in tenths of a second
SETTI
Trickle interval in tenths of a second
SETID
Unit ID
SETROLL
Rollover month
SETPRE
Characters to pre-pend to any scan
SETEXT
Extract command to use
SETDCI
DCI to pass for validation purposes
SETLOG
Log verbosity
SETEXP
Whether to react to expiration dates (1=enabled)
SETEXP0 shuts off expiration dates
SETCARD
List of prefixes to associate with cards
SETCON
Attempt to enable Config menu by passing code
SETLO
Whether LOC and OP can be used without the SET prefix (0 means you can)
SETIS34
Is this being used with Salesware version 3.4 (1 means it is)
SETCNTR
Set the counter (1 means it’s on)
SETRECINT
Set reconnect interval
SETCPN
Set checkpoint name
SETCPV
Set checkpoint value
SETHOTLIST
Tells you how many Hotlist entries there are
SETNODEC
Set the prefixes that are not decrypted
SETWAV
Set delay for WAV file (in tenths of a second)
SETRF
Activate RF support (1 means it is active)
SETPIC
Activates viewing of pictures
SETPINT
Sets auto-display of picture interval (tenths of a second)
SETGITEXT
Sets text to show below picture
 
Log-in:
 
Location: 01 – This represents the lift or entrance point and is posted at each lift/entrance. This is unique per lift/entrance.
 
Description: setloc01
 
Operator: JSMITH – This represents the operator and is on badge they wear
 
Description: setopjsmith