Manual settings for scan location, date and/or time
Configuration code logic in GateKeeper module allows for manual setting of scan date and/or time as well as location using SETDATE and SETLOC functions either by manual entry or scanning a barcode with SETDATE or SETLOC information. In order to display Date and Location, the Gatekeeper.INI file must be updated.
The use of SET commands operate as follows: SETDATE09/25/2010 8am sets the DATE & TIME for trickling any subsequent scans to the date and time scanned. The text can be any parse-able date. 2010-09-25 08:00 would work for example. If no time is specified it is assumed to be 12:00 AM of the date scanned.
• SETDATE with no argument, resets the gate back to normal mode (current date, time and live).
• SETLOCGATE9 sets the gate location, GATE9 in this case.
• SETLOC with no argument, sets the location back to the default defined in the Gatekeeper.INI
Note: Date and/or Time Configuration Code settings can be found within the Salesware .INI Settings Reference document.