Access Control : Installing and using GateKeeper module : Configuration : Manual settings for scan location, date and/or time
 
Manual settings for scan location, date and/or time
 
Configuration code logic in GateKeeper module allows for manual setting of scan date and/or time as well as location using SETDATE and SETLOC functions either by manual entry or scanning a barcode with SETDATE or SETLOC information. In order to display Date and Location, the Gatekeeper.INI file must be updated.
The use of SET commands operate as follows: SETDATE09/25/2010 8am sets the DATE & TIME for trickling any subsequent scans to the date and time scanned. The text can be any parse-able date. 2010-09-25 08:00 would work for example. If no time is specified it is assumed to be 12:00 AM of the date scanned.
SETDATE with no argument, resets the gate back to normal mode (current date, time and live).
SETLOCGATE9 sets the gate location, GATE9 in this case.
SETLOC with no argument, sets the location back to the default defined in the Gatekeeper.INI
 
Note: Date and/or Time Configuration Code settings can be found within the Salesware .INI Settings Reference document.