ScanMan config settings:
• IP Address of SalesEZ computer: IP172.20.1.251
Resulting setting in the ScanMan.INI file: IP=172.20.1.251
• Port: PORT4203
Resulting setting in the ScanMan.INI file: Port=4203
• Trickle Delay: Number of seconds (in tenths of seconds) to wait until offline scans begin trickling to SalesEZ application
Resulting setting in the ScanMan.INI file: TrickleDelay=100
• Trickle Interval: Time interval at which trickled scans (offline scans) are sent to SalesEZ application (in tenths of seconds)
Resulting setting in the ScanMan.INI file: TrickleInterval=30
• Time Out: Number of seconds (in tenths of seconds) to wait until ScanMan disconnects from SalesEZ application
Resulting setting in the ScanMan.INI file: Timeout=30
• Rollover Month: ROLL6
Resulting setting in the ScanMan.INI file: Rollover=6
• Prepend: B44614485 – used only when truncated sixteen digit card numbers are encoded on the pass
Resulting setting in the ScanMan.INI file: Prepend=B44614485
• Log: LOG0 – allows you to increase or decrease logging on the scanner itself
Resulting setting in the ScanMan.INI file: Log=0
• Expiration Date Checking: EXP0 – 0 disables, 1 enables
Resulting setting in the ScanMan.INI file: Exp=0
• Reconnect Interval: the number of scans that must elapse before ScanMan module tries to reconnect – default is 25
Resulting setting in the ScanMan.INI file: RecInt=25
• Resettable Counter: disable or enable the resettable counter. Default is 1 (enabled)
Resulting setting in the ScanMan.INI file: Cntr=1
• Setting that controls access to the Config menu if not included the Config menu is always accessible assuming the ScanMan.INI setting shows: ConfigCode=MATTY
Note: The code must be in all CAPS
The barcode that accesses Config menu assuming setting above is in place:
• Barcode that disables the Config menu again:
• ScanMan can be configured to take different prefixes to denote cards
Resulting setting in the ScanMan.INI file: Card=MB
Note: You can also allow a blank prefix, but you must specify at least two other prefixes around them.
Example:
Card=M B allows a blank prefix before the card number.
• DCI to send in with every checkandvalidate pass as well as validate pass
Resulting setting in the ScanMan.INI file: DCI=PASS PARK ALLDAY
• Display the number of records in the current Hot List - Helpful when verifying that the current Hotlist is up to date. The count of records in the Hotlist loaded on the scanner can be compared to the number of records included in the current Hotlist table in the server data.
No ScanMan.INI setting is created with the scan of this barcode. It is only used to get information regarding the number of records contained in the Hotlist loaded on the scanner.
• CheckpointName -Typically used with GateKeeper module, but can also be used with ScanMan module when monitoring capacity counts within a specific location. Limited to ten characters (anything beyond ten is truncated in the data). Used with CheckPointValue (described below).
Resulting setting in the ScanMan.INI file: CheckPointName=WATERPARK
• CheckpointValue -Typically used with GateKeeper module, but can also be used with ScanMan when monitoring capacity counts within a specific location. Value is IN or OUT and is used with the CheckPointName setting (described above).
Resulting setting in the ScanMan.INI file: CheckPointValue=IN